FAQ   Dictionary   Newsletter   PRIVACY    IT | EN | ES
SLIMFLUX 60x60 UGR<19
SLIMFLUX
  • Ultra flat LED appliances for direct lighting; UGR<19.
  • Same flow as the 4x18W module with fluorescent tubes.
  • UGR19 photometric: UGR19 is required for places where visual display units are used.
  • Side heat dissipation.
  • Possible installation: suspended or recessed mounting.
  • Immediate switch-on.
  • Maintenance-free.
  • Color tonality Natural white.
  • Extremely high color rendering: Ra>80.
  • Fuse for mains protection.
  • Working position: universal.
  • IP40.
  • White painted metal body.
  • Adjustable suspension wires kit available with separate kit, code KTLP-SPB.
  • Remote power supply included.
  • Do not use with dimmer.
  • DRIVER (included in the panel package) INFO: - Input voltage 100-240Vac - Input current 0.5A max - Frequency 50/60Hz - Power factor =0.9 - Output Voltage: 35-48Vdc - Output current 840mA 5% - Output power 40W max - Driver dimensions: 140x45x30mm.
Item Characteristics
Code LP6060NWB-UGR
Nominal Power 40 W
Base cavi/wires
Nominal Flux 3300 Lumen
Input voltage 220-240
Light Tonality Natural white
Colour temperature 4000 K
Lenght 595 mm
Lenght 1 595 mm
Lenght 2 13 mm
Weight 3000 gr
Performance
Photometry LP6060NWB-UGR
Irc/Ra >80
Lifetime 25000 h
Energy Class A+
Equivalence with incandescent lamp W
Tech Info
Dimmable NO
Number of ON-OFF cycles 100000
Power Factor 0,97
Warm-up time up to 60 % of the full light output Instant Full Light
Lamp start time <0,2s
Mercury (mg) 0
LLMMF - Lamp lumen maintenance factor 70%
T (C) Working environment Temp. -25C / +35C
Fulfilled Directives and norms 2009/125/EC * Ecodesign
1194/2012 * Regulation for Ecodesign
2015/1428 * Regulation for Ecodesign
2010/30/EU * Energy Labelling
874/2012 * Regulation for Energy Labelling
2011/65/EU * RoHS
2012/19/EU * RAEE
2014/30/EU * EMC
2014/35/EU * LVD

CEI EN 55015:2014 (+A1:2016)
CEI EN 60598-1:2015 (+EC:2015/+EC:2016)
CEI EN 60598-2-1:1997
CEI EN 60598-2-2:2012
CEI EN 61000-3-2:2015
CEI EN 61000-3-3:2014 (+EC:2014)
CEI EN 61547:2010
CEI EN 62031:2009 (+A1/+A2:2015)
CEI EN 62471:2010
IEC/TR 62471-2:2009
CEI 34-141:2012
P.I.: 03312240488